smart memocheck_box_outline_blankTakcheck_box_outline_blankNie OLLIcheck_box_outline_blankTakcheck_box_outline_blankNie MPPcheck_box_outline_blankTakcheck_box_outline_blankNie GasTest delta3check_box_outline_blankTakcheck_box_outline_blankNie HUNTERcheck_box_outline_blankTakcheck_box_outline_blankNie Druktest maxcheck_box_outline_blankTakcheck_box_outline_blankNie Menu-guided pressure test procedures for carrying out pressure tests on district heating pipes
according to AGFW FW 602 (Germany):
- Differential pressure measurement method (air)
- Pressure measurement method (air)
- Simultaneous pressure measurement (air)
- Water pressure testThe option package includes the use of the additional functions “option remote control“ and
„option air volume measurement“ in the smart memo. The period of use is one year. The
annual fee is due on date of order in terms of prepaid charges. After expiration of the period of
use the option package will be inactivated. A new or subsequent order of the option package
can be placed at any time. The annual fee can be payed for multiple years in advance.
This option package can only be used in conjunction with the motor tes pumps MPP 30-30/
MPP 70-35 and the smart memo. Another requirement is the option „flow measurement“ in
the MPP 30-30/MPP 70-35.
The following services are included:
Option remote control
This option means that the smart memo and the MPP 30-30/MPP 70-35 can communicate
with each other and exchange measured values. Test sequences for water pressure tests can be
carried out partially automated. The smart memo controls the pump and starts/stops the
pressure control/maintenance at the right time.
Option air volume measurement
With the help of this option in combination with the MPP 30-30/MPP 70-35 a determination of the residual air in the tested pipe is performed.
Directly after the end of the pressure build-up phase, a rating for the absence of air in the pipe
is displayed. With the air volume measurement, the smart memo can detect critical high air
contents at an early stage and the user is spared unnecessary time and effort. For the time
being, this function is only available for the contraction method (W 400-2/W 101/EN805).
This option can currently only be configured after the LTE-GPS Option (222610) has been
selected.Menu-guided test procedures for carrying out pressure tests on wastewater pipelines and
manholes in accordance with the regulations EN 1610 (Europe), DWA-A 139 (Germany) and
DWA-M 149-6 (Germany).
This option includes the following menu items in the device:
Wastewater Procedure Air : Carry out the tests with the test medium air in accordance with the
regulations mentioned. EDS2-P 1 bar pressure sensor required.
Wastewater Procedure water: Carry out the tests with the test medium water in accordance
with the regulations mentioned. EDS2 level probe and EDS2 dosing valve required.
The menu item "Wastewater Procedure Water" will only be completed in Q2/2023 and can be
installed via an update of the device without additional booking as soon as it is available.Annual fee for sending measurements via the Esders Connect app (Android, iOS,
Windows) by means of a flat rate.
The annual fee must be paid in advance (prepaid) and is due at the time of booking. It is device-specific, can be renewed at any time and can also be paid for several years in advance in order to plan the period of use long-term. When the term expires, measurements can still be sent. However, these are billed individually and debit the measurement quota. The credit for this can be recharged via the measurement package (item 222550).
Menu-driven test procedures for pressure tests on water pipes according to rules and regulations of EN 805 (Europe):
- Contraction procedure
- Normal procedureIn combination with the Esders Connect app (Android, iOS, Windows), enables the live measured values of the device to be displayed on a smartphone, tablet or PC (Android, iOS, Windows).
The zero point can also be set manually and the alarm deactivated. The function only applies to the "above-ground testing" use case (HUNTER) respectively "leak detection" (HUNTER Tracer Gas).Menu-guided test sequence for carrying out pressure tests on gas pipelines in accordance with DVGW G 469 C3 procedure (Germany).
For this menu item, the pressure curve is not evaluated by the smart memo, as this test procedure is usually evaluated by an expert.
The test measurement data is available as an Excel list in Esders Connect.Annual fee for sending measurements via the Esders Connect app (Android, iOS,
Windows) by means of a flat rate.
The annual fee must be paid in advance (prepaid) and is due at the time of booking. It is device-specific, can be renewed at any time and can also be paid for several years in advance in order to plan the period of use long-term. When the term expires, measurements can still be sent. However, these are billed individually and debit the measurement quota. The credit for this can be recharged via the measurement package (item 222550).Menu-driven pressure test procedures for gas pipelines according to UNE 60311 (Spain):
UNE 60311: gas lines designed for MOP <= 5 barMenu-driven pressure test procedures for gas pipelines according to following standards
(Spain):
UNE 60310: gas lines designed for 5 bar < MOP <= 16 bar
UNE EN 1594: gas lines designed for MOP > 16 barIn combination with the Esders Connect app (Android, iOS, Windows), enables the live measured values of the device to be displayed on a smartphone, tablet or PC (Android, iOS, Windows).
The zero point can also be set manually and the alarm deactivated. The function only applies to the "above-ground testing" use case.Annual fee for sending measurements via the Esders Connect app (Android, iOS, Windows) by means of a flat rate.
The annual fee must be paid in advance (prepaid) and is due at the time of booking. It is device-specific, can be renewed at any time and also be paid for several years in advance in order to plan the period of use long-term. When the term expires, measurements can still be sent. However, these are billed individually and debit the measurement quota. The credit for this can be recharged via the measurement package (item 222550).Annual fee for sending measurements via the Esders Connect app (Android, iOS, Windows) by means of a flat rate.
The annual fee must be paid in advance (prepaid) and is due at the time of booking. It is device-specific, can be renewed at any time and can also be paid for several years in advance in order to plan the period of use long-term. When the term expires, measurements can still be sent. However, these are billed individually and debit the measurement quota. The credit for this can be recharged via the measurement package (item 222550).Menu-driven pressure test procedures for water pipes according to German DVGW W 400-2
- Contraction procedure
- Accelerated normal procedure
- Normal procedure
- Influence-minimized normal procedurezintegrowana pompa o natężeniu przepływu ok. 20 l/h
Pompa przesyła gaz przez różne dostępne sondy
do sensorów. Nypel, zawierający filtr, na górnej stronie
obudowy służy do podłączenia sond do przyrządu.
Czas pracy zostaje skrócony o ok. 40% w porównaniu do
wersja dyfuzyjnej.
Wymiary przyrządu ze zintegrowaną pompą: 171 x 78 x 43 mm
Waga: ok. 380 gMożliwe zakresy pomiaru/wskazań (podlega konfiguracji):
ppm 0 - 22 000 ppm metanu
DGW 0 - 100% DGW metanu
% obj. 0 - 100 % obj. metanu
Dokładność zależy od wybranego zastosowania
i można ją ustawić w określonych granicach.Opcjonalny pomiar gazów palnych i
dwutlenku węgla (podwójny czujnik IR)
Zakresy pomiarowe:
DGW 0 - 100% DGW metanu
% obj. 0 - 100 % obj. metan
CO2 0 - 5% obj.
Dokładność zależy od wybranego zastosowania.LTE GPS module option.
LTE and GPS module for simple, direct transmission of
Measurement and GPS position data e.g. to an e-mail address. An LTE data package is included
and permits the sending of 100 measurements (report e.g. in PDF format).